 125W Triple Output with PFC Function
Features :
P P T- 1 2 5
series
Universal AC input / Full range Built-in active PFC function Protections: Short circuit / Overload / Over voltage PWM control and regulated High power density 6.117W/inch3 LED indicator for power on 100% full load burn-in test 125W with 18CFM FAN 5"x3" compact size 3 years warranty
SPECIFICATION
MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT PPT-125A CH1 3.3V 10A CH2 5V 8A CH3 12V 0.5A PPT-125B CH1 5V 11.5A CH2 12V 3A CH3 -12V 0.5A PPT-125C CH1 5V 11A CH2 15V 2.5A CH3 -15V 0.5A PPT-125D CH1 5V 7A CH2 24V 2.5A CH3 12V 0.5A
CURRENT RANGE (convection) 1 ~ 10A RATED POWER (convection) 79W OUTPUT RATED POWER (18CFM FAN) 98.8W VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP., HUMIDITY WORKING TEMP. ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE
0.8 ~ 8A 0.05 ~ 0.5A 1 ~ 11.5A 0.3 ~ 3A 99.5W 124.46W CH1:4.75 ~ 5.25V 3.0% 5.0% 0.5% 3.0% 0.5% 3.0%
0.05 ~ 0.5A 1 ~ 11A 100W 125.15W
0.25 ~ 2.5A 0.05 ~ 0.5A 1 ~ 7A 101W 126.43W
0.25 ~ 2.5A 0.05 ~ 0.5A
CURRENT RANGE (18CFM FAN) 1 ~ 12.5A 0.8 ~ 10A 0.05 ~ 0.63A 1 ~ 14.38A 0.3 ~ 3.75A 0.05 ~ 0.63A 1 ~ 13.75A 0.25 ~ 3.13A 0.05 ~ 0.63A 1 ~ 8.75A 0.25 ~ 3.13A 0.05 ~ 0.63A
RIPPLE & NOISE (max.) Note.2 100mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 240mVp-p 120mVp-p CH1:3.13 ~ 3.46V 3.0% 5.0% 0.5% 3.0% 0.5% 3.0% 6.0% 0.5% 5.0% 6.0% 0.5% 5.0% CH1:4.75 ~ 5.25V 3.0% 5.0% 0.5% 3.0% 0.5% 3.0% 6.0% 0.5% 5.0% CH1:4.75 ~ 5.25V 3.0% 5.0% 0.5% 3.0% 0.5% 3.0% 6.0% 0.5% 5.0%
1000ms, 30ms/230VAC 24ms/230VAC 90 ~ 264VAC 47~63Hz PF>0.93/230VAC 75%
2000ms, 30ms/115VAC at full load
24ms/115VAC at full load 127 ~ 370VDC PF>0.98/115VAC at full load 78% 78% 78%
1.7A/115VAC 0.75A/230VAC COLD START 24A/230VAC <2mA / 240VAC 130 ~ 160% rated output power Protection type : Fold back current limiting, recovers automatically after fault condition is removed CH1:3.6 ~ 4.45V CH1:5.75 ~ 6.75V CH1:5.75 ~ 6.75V Protection type : Hiccup mode, recovers automatically after fault condition is removed -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 0.05%/ , 10 ~ 95% RH (0 ~ 50 CH1:5.75 ~ 6.75V
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC / 70% RH
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMC EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
(Note 4)
HARMONIC CURRENT EMS IMMUNITY MTBF OTHERS DIMENSION PACKING
NOTE
Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A 94.7Khrs min. MIL-HDBK-217F (25 ) 127*76.2*34.6mm (L*W*H) 0.37Kg; 36pcs/14.3Kg/0.79CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Heat Sink HS1,HS2 & HS3 can not be shorted.
File Name:PPT-125-SPEC 2008-10-22
125W Triple Output with PFC Function
Mechanical Specification
127 5 115.6
P P T- 1 2 5
series
Unit:mm
6.4
HS3 SVR1 HS1 LED1 1 2 3 4 5 6 7 8 9 10 CN4
76.2
64.8
FS1 T2A 250VAC
1 2 3 CN1
HS2
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No. 1 2 3 Assignment AC/L No Pin AC/N Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent
43.
Air flow direction
5
DC Output Connector (CN4) : JST B5P-VH*2 or equivalent
Pin No. 1 2,3 4~8 9,10 Assignment CH3 CH2 GND CH1 Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent
34.6
HS1, HS2 & HS3 can not be shorted
3max.
Block Diagram
I/P EMI FILTER & RECTIFIERS PFC CIRCUIT POWER SWITCHING RECTIFIERS & FILTER RECTIFIERS & FILTER RECTIFIERS & FILTER REGULATOR
fosc : 100KHz
V3
V2 +5V COM DETECTION CIRCUT
FG
PWM & PFC CONTROL
O.V.P.
Derating Curve
Output Derating VS Input Voltage
125
100
Forced air 18CFM
100
90 80 70
Free air Convection
70
LOAD (%)
50 40 20
LOAD(%)
0 10 20 30 40 50 60 70 (HORIZONTAL)
60 50 40
-20
85
100
115
135
155
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (V) 60Hz
File Name:PPT-125-SPEC 2008-10-22


▲Up To Search▲   

 
Price & Availability of PPT-125

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X